Specification
|
|
Manufactured in:
|
Australia by an Australian owned family company
|
|
Standard Compliant:
|
AS1735 part 17
|
|
Application:
|
Residential use only
|
|
Installation:
|
|
External only
|
|
Crane in, dismantle or man handle
|
|
|
Drive system
|
Water Hydraulic with direct acting cylinders on each side of the lift car
|
|
Suppy Voltage
|
240 volt 15 amp
|
|
Travels:
|
Up to 3.5 metres
|
|
Lift Speed:
|
N/A
|
|
Lifting Capacity:
|
250kg (2 people including 1 in a wheel chair)
|
|
Lift Tower:
|
|
Built as a free standing unit, weighing approx 350kg the lift is fabricated from aluminium and fitted with folded white colourbond panels section providing a a smooth flush surface within the lift shaft. A Colourbond hat is attached to the top of the shaft: 2300mm above the top landing to the required height of the cylinder extension to achieve weatherproofing and exhaust ventilation. A polycarbonate translucent panel is fitted to the side of the shaft to provide natural lighting to the lift car.
Weatherproof awnings are fitted above the landing doors as required
|
|
|
Pit Depth:
|
80mm
|
|
Car Size:
|
|
Individually built to the customers requirements up to a maximum floor space of 1.3m2 Standard Size - 900mm wide x 1300mm deep x 2000mm high with a clear door opening of 820mm
|
|
|
Car Configuration:
|
|
Single entry
|
|
Dual entry - through car
|
|
|
Car Fit out:
|
|
The lift car walls are internally lined with flat white colourbond whilst the floor is fitted with an indoor/outdoor carpet. The lift car is not provided with a roof
|
|
|
|
Standard features are
|
|
* Stainless steel handrail
|
|
* Non - slip floor covering indoor/outdoor carpet
|
|
* Emergency telephone recessed into a box
|
|
* Two recessed down lights
|
|
* 2 x Photo electric sensors across the door entrance
|
|
|
Landing Doors:
|
|
Fabricated from aluminium the metal doors are lined on the inside with white colourbond leaving the frame exposed to the outside. 1850mm in height and 860mm wide the doors are swing action.
|
|
|
|
|
All doors are fitted with mechanical electric interlock, an externally mounted fully adjustable automatic door closer, full length pull handle and a mesh vision panel.
|
|
Automatic door operators are available as an optional extra
|
|
|
|
Stations:
|
|
Mounted on a stainless steel plate with protruding buttons the electric controls are automatic in operation
|
|
Key lockable at upper & lower landing to prevent unwanted users
|
|
Illuminated indications
|
|
Weatherproof stations at each landing
|
|
|
Safety features:
|
|
* Key lockable push button controls.
|
|
* Emergency stop button in the lift car
|
|
* Back up battery power for lighting & lowering of the car
|
|
* Emergency manual lowering facility provided in the machine cabinet
|
|
* A non-reversal timer of 5 seconds is fitted to allow the rider in the car to open the landing door once the car has stopped without the threat of the car being called by another operator.
|
|
|
Machine Cabinet:
|
|
Fabricated from metal and painted in silver hammer the machine cabinet is suitable for external or internal installation.
|
|
The cabinet is fitted with a key lockable door and contains the hydraulic
|
|
power unit, hydraulic control valves, electrical control board, emergency power supply and cabinet light. The emergency tools and instructions are located within this cabinet.
|
|
|
|
The cabinet size is 1800mm in height x 600mm in width x 300mm in depth
|
|
|
Maintenance:
|
We recommend that the lift be serviced at no greater intervals than 12 months. This will keep the lift in a safe and serviceable condition.
|
|
Warranty:
|
12 months on all parts and labour excluding misuse and/or malicious damage.
|
|
Work by others:
|
|
* All building work such as the concrete slab for the lift and entry pathway as well as providing a penetration at the upper landing verandah
|
|
* Supply of a 240V. 15A electrical circuit to the Machine Cabinet.
|
|
* Supply and connection of a telephone line to the lift shaft terminating in the junction box provided by the lift installers (extension of the residence phone).
|
|
|
|
All changes must be in compliance with the lift code and manufacturer reserves the right to approve or refuse any changes.
|
|
Gemini:
|
|
|
Gemini being installed:
|
|